ARE 5.0 Project Development & Documentation Exam Prep

Previous Chapter:
Objective 1.1: Analyze the Integration of Architectural Systems and Technologies to Meet Project Goals

Currently Viewing:
Objective 1.2: Determine the Size of Mechanical, Electrical, Plumbing Systems and Components to Meet Project Goals

Course Videos
Practical Applications - Upgrade to Pro

Up Next:
Objective 1.3: Determine the Size of Structural Systems to Meet Project Goals

You have reached one of our paid video tutorials for the course:

ARE 5.0 Project Development & Documentation Exam Prep

You can either log in to view it or learn more about our memberships.

Hydronic Example - Radiators

7m 40s

In this ARE 5.0 NCARB-approved Project Development and Documentation Exam Prep course you will learn about the topics covered in the ARE 5.0 PDD exam division. A complete and comprehensive curriculum, this course will touch on each of the NCARB objectives for the ARE 5.0 Project Development and Documentation Exam.

Instructor Mike Newman will discuss issues related to the development of design concepts, the evaluation of materials and technologies, selection of appropriate construction techniques, and appropriate construction documentation.

When you are done with this course, you will have a thorough understanding of the content covered in the ARE 5.0 Project Development and Documentation Exam including integration of civil, structural, mechanical, electrical, plumbing, and specialty systems into overall project design and documentation.

Transcript summarylog in to access this content in full.

And then in the basement, because I have such a different type of heat loss in the basement, so the basement counts as square footage but I'm not gonna be losing anywhere near the same amount of heat loss through that basement wall because the soils will actually kind of, even though they're very very low from an R value standpoint, they're actually quite useful as a heat sync standpoint so they kind of keep that heat generally around the building so it just doesn't get as cold outside when it's the outside is the ground when you're in the basement as it does in the air up above. So I need to have a system down in the basement but I don't need to have anywhere near the same amount of actual radiators down in the basement. So you might actually get away with just having the hot water pipes just by themselves run around the perimeter, maybe up in the ceiling even and maybe I'd run them back and forth a little bit.

Log in to access files

From the course:
ARE 5.0 Project Development & Documentation Exam Prep

Duration: 36h 46m

Author: Mike Newman